Ürün merkezi
Ana sayfa > Ürün Merkezi > Düşük voltaj kablosu > PVC Cable 4X6mm2/4X6mm 8mm Cu PVC Armoured Power Cable Price

    PVC Cable 4X6mm2/4X6mm 8mm Cu PVC Armoured Power Cable Price

  • Sınıflandırmaları:
    Düşük voltaj kablosu
  • paylaşmak:
  • QR Kodu:
  • Bırakma süresi:
    2025-08-07 05:40:17
  • Anında sorgulama

Detailed Information on PVC Cable 4X6mm²/4X6mm 8mm Cu PVC Armoured Power Cable

1. Specification Parameters

The PVC Cable 4X6mm²/4X6mm 8mm Cu PVC Armoured Power Cable is a Multi-Core, low-Voltage Cable designed for reliable power distribution in diverse environments. Its specifications are engineered to balance performance, safety, and practicality, making it suitable for both indoor and outdoor applications.
Conductor Specifications:
  • Material: High-purity electrolytic copper with a minimum purity of 99.95%, ensuring excellent electrical conductivity (58 MS/m). The copper is annealed to enhance Flexibility, reducing brittleness during installation and handling.

  • Stranding: Conductors are stranded with a class B stranding pattern (per IEC 60228), consisting of multiple Copper Wires twisted together. For 6mm² conductors, the stranding configuration is 7 strands of 1.04mm diameter; the 8mm² conductor (where included) uses 7 strands of 1.2mm diameter. This design improves flexibility and resistance to fatigue from bending.

  • Cross-Sectional Area: Available in two main configurations:

    • 4X6mm²: Four 6mm² conductors, typically used for three-phase power (L1, L2, L3) and neutral (N).

    • 4X6mm² + 1X8mm²: Four 6mm² conductors plus one 8mm² conductor, where the 8mm² serves as a protective earth (PE) conductor, providing enhanced grounding capacity.

  • Resistance: At 20°C, the DC resistance is ≤3.08Ω/km for 6mm² conductors and ≤2.31Ω/km for the 8mm² conductor, ensuring minimal energy loss during transmission.

Insulation Parameters:
  • Material: Polyvinyl chloride (PVC) insulation, formulated with plasticizers and stabilizers to enhance flexibility and thermal resistance. The insulation is flame-retardant, meeting IEC 60332-1 standards.

  • Thickness: 0.8mm for 6mm² and 8mm² conductors, providing sufficient electrical isolation. The insulation has a dielectric strength of ≥15kV/mm, preventing electrical breakdown under normal operating conditions.

  • Temperature Rating: Long-term continuous operating temperature of 70°C; short-circuit (5-second duration) temperature tolerance of 160°C, suitable for handling temporary overloads.

  • Insulation Resistance: Exceeds 500MΩ·km at 20°C, ensuring effective protection against leakage current.

Armouring Specifications:
  • Material: Galvanized Steel Tape (thickness 0.3mm) or steel wire (diameter 1.2mm), depending on the specific design. The steel is galvanized with a zinc coating (≥80μm thickness) to resist corrosion, critical for outdoor and underground installations.

  • Application Method: Steel tape is spirally wound with an overlap of 15-20% to form a continuous protective layer; steel wire (when used) is helically wrapped with a lay length of 12-16 times the cable diameter. Both methods provide robust protection against mechanical impact, soil pressure, and rodent damage.

Sheath Parameters:
  • Material: PVC Sheath, formulated with UV stabilizers and antioxidants to resist degradation from sunlight and environmental exposure. The sheath is also resistant to oils, dilute acids, and alkalis, enhancing durability in harsh environments.

  • Thickness: 1.2mm for the 4X6mm² configuration and 1.4mm for the 4X6mm² + 1X8mm² configuration, providing additional mechanical protection.

  • Mechanical Properties: Tensile strength ≥12MPa, elongation at break ≥150%, ensuring the sheath can withstand stretching and impact during installation and operation.

Voltage Rating: Rated for 0.6/1kV (phase-to-earth/phase-to-phase), compliant with IEC 60502-1 and BS 6346 standards, making it suitable for low-voltage distribution systems in residential, commercial, and industrial settings.
Current-Carrying Capacity (Ampacity):
  • In Air (30°C Ambient): 4X6mm² cable has an ampacity of 45A; 4X6mm² + 1X8mm² cable is 45A (phase conductors) with the 8mm² earth conductor rated for 35A.

  • In Soil (25°C Ambient): 40A for phase conductors in both configurations, with the 8mm² earth conductor rated for 30A.

  • In Conduit (30°C Ambient): 40A for phase conductors, ensuring safe operation in enclosed spaces.

Mechanical Parameters:
  • Outer Diameter: 18mm for 4X6mm²; 20mm for 4X6mm² + 1X8mm².

  • Minimum Bending Radius: 12 times the outer diameter for fixed installations (216mm for 4X6mm²; 240mm for 4X6mm² + 1X8mm²) and 20 times for dynamic applications (360mm and 400mm, respectively).

  • Weight: 0.65kg/m for 4X6mm²; 0.75kg/m for 4X6mm² + 1X8mm², influencing handling and transportation requirements.

2. Characteristic Uses

The PVC Cable 4X6mm²/4X6mm 8mm Cu PVC Armoured Power Cable’s design and performance make it versatile across numerous low-voltage distribution scenarios, each leveraging its protective and conductive properties.
Residential Applications:
  • Multi-Storey Buildings: Used as 分户主线 (household main lines) in apartments and townhouses, distributing power from the building’s main distribution board to individual units. The 4X6mm² configuration handles three-phase power for larger appliances like electric stoves and HVAC systems, while the 8mm² earth conductor (where included) enhances safety by providing a reliable grounding path.

  • Detached Homes: Deployed for underground service entrances from the utility pole to the home’s breaker box, with the PVC armouring protecting against soil pressure and garden equipment damage.

Commercial Applications:
  • Small to Medium Businesses: Powers lighting, air conditioning, and office equipment in shops, restaurants, and offices. The cable’s flame-retardant sheath and armouring make it suitable for installation in ceiling voids and wall cavities, reducing fire risks.

  • Retail Spaces: Used in shopping malls for connecting kiosks, display lighting, and POS systems. Its flexibility allows for easy routing around structural obstacles.

Industrial Applications:
  • Light Industrial Facilities: Connects small motors, pumps, and control panels in workshops and warehouses. The armouring resists damage from forklifts and heavy machinery, while the PVC Insulation withstands occasional oil or chemical exposure.

  • Control Circuits: In manufacturing plants, the 4X6mm² + 1X8mm² configuration is used for machinery control loops, where the dedicated earth conductor ensures safe operation of emergency stop systems.

Infrastructure and Municipal Uses:
  • Outdoor Lighting: Powers streetlights, park lighting, and security lighting. The UV-stabilized sheath and armouring protect against weathering and vandalism.

  • Utility Distribution: Used in underground networks to connect transformers to residential and commercial areas, with the armouring preventing damage from ground movement and construction activities.

Specialized Environments:
  • Damp Locations: Suitable for basements, crawl spaces, and outdoor canopies, as the PVC sheath and armouring resist moisture ingress.

  • Corrosive Areas: Deployed in areas with mild chemical exposure, such as near swimming pools (chlorine) or agricultural facilities (fertilizers), thanks to the cable’s chemical-resistant properties.

3. Material and Style

The materials and design of the cable are carefully selected to optimize performance, durability, and ease of installation, ensuring it meets the demands of diverse applications.
  • High-purity copper is chosen for its superior conductivity, which minimizes energy loss. Annealing at 400-500°C softens the copper, making it easier to strand and reducing the risk of cracking during bending. The stranded design increases flexibility compared to solid conductors, particularly important for installations requiring tight turns.

  • PVC insulation is a cost-effective choice with good electrical and mechanical properties. It is compounded with phthalate-free plasticizers to enhance flexibility (especially in cold temperatures) and heat stabilizers to resist degradation at 70°C. The insulation is color-coded for phase identification: brown (L1), black (L2), gray (L3), blue (neutral), and green/yellow (earth), ensuring correct installation.

Armouring Material:
  • Galvanized steel provides robust mechanical protection. The zinc coating acts as a sacrificial anode, preventing rust and extending the cable’s lifespan in humid or underground environments. Steel tape armouring is preferred for its flexibility and uniform coverage, while steel wire armouring offers higher tensile strength for applications requiring additional pull resistance.

Sheath Material:
  • The outer PVC sheath is formulated with a high molecular weight resin to enhance impact resistance. UV stabilizers (such as carbon black) protect against sunlight-induced degradation, making it suitable for outdoor use. The sheath’s smooth surface reduces friction during installation, easing pulling through conduits or trenches.

Cable Style:
  • The cable has a round, compact design with conductors twisted together to form a stable core. The armouring is applied directly over the Insulated Conductors (with a thin inner liner to prevent abrasion), followed by the outer sheath. This layered structure ensures each component performs its function without compromising others.

  • Color coding of conductors simplifies installation, with the green/yellow striped earth conductor (where included) clearly distinguishable from phase and neutral conductors. The outer sheath is typically black, providing a neutral appearance suitable for various environments.

4. Production Process

The manufacturing process of the PVC Cable 4X6mm²/4X6mm 8mm Cu PVC Armoured Power Cable involves several precision steps to ensure quality, consistency, and compliance with standards.
Conductor Stranding:
  • Wire Drawing: Copper rods (8mm diameter) are drawn through diamond dies to reduce their diameter to 1.04mm (for 6mm²) and 1.2mm (for 8mm²). This process increases tensile strength while maintaining conductivity.

  • Annealing: The drawn wires are annealed in a continuous furnace under a nitrogen atmosphere to relieve internal stresses. Annealing temperatures range from 400°C to 500°C, softening the copper for easier stranding.

  • Stranding: Wires are twisted together in a planetary stranding machine to form 6mm² and 8mm² conductors. The stranding lay length is 16-20 times the conductor diameter, ensuring uniformity and flexibility.

Insulation Extrusion:
  • Each conductor is fed into an extrusion line where PVC insulation is applied. The PVC compound (resin + plasticizers + stabilizers) is melted at 160-180°C and extruded over the conductor using a cross-head die, forming a uniform layer 0.8mm thick.

  • Cooling: The insulated conductor is cooled in a water bath to solidify the PVC, ensuring dimensional stability.

  • Color Coding: During extrusion, pigments are added to the PVC compound to achieve the required phase colors (brown, black, gray, blue, green/yellow).

Cabling:
  • Insulated conductors are gathered and twisted together in a cabling machine to form the multi-core structure. For the 4X6mm² + 1X8mm² configuration, the 8mm² earth conductor is integrated into the twist. A small amount of filler (polypropylene rope) is added to ensure a round core, facilitating uniform armouring.

Armouring:
  • Steel Tape Application: Galvanized steel tape (0.3mm thick) is unwound from reels and spirally wrapped around the cabled core with a 15-20% overlap. The tape is formed to match the core’s diameter using forming rollers, ensuring a tight fit.

  • Steel Wire Application (if used): Galvanized steel wires (1.2mm diameter) are helically wrapped around the core using a rotating head, with a lay length of 12-16 times the core diameter. Tension is carefully controlled to avoid damaging the insulated conductors.

Sheath Extrusion:
  • The Armoured Core is fed into a second extrusion line for application of the outer PVC sheath. The sheath compound (with UV stabilizers) is melted at 170-190°C and extruded over the armouring, forming a 1.2mm or 1.4mm thick layer.

  • Cooling and Sizing: The Sheathed Cable is cooled in a water bath, and a sizing die ensures the outer diameter is consistent. The surface is smoothed to remove imperfections.

Quality Control Testing:
  • Conductor Testing: Resistance measurement using a micro-ohmmeter to verify conductivity.

  • Insulation Testing: Dielectric strength testing (applying 2.5kV for 5 minutes) and insulation resistance testing with a megohmmeter.

  • Armouring and Sheath Testing: Tensile strength and elongation of the sheath, adhesion between sheath and armouring, and corrosion resistance of the galvanized steel (salt spray test per ASTM B117 for 96 hours).

  • Dimensional Checks: Verification of conductor size, insulation thickness, armouring coverage, and outer diameter using precision calipers.

Spooling:
  • The finished cable is wound onto wooden or steel spools, with standard lengths of 100m, 250m, and 500m. Each spool is labeled with product details, batch number, and compliance marks.

5. Packaging

Packaging is designed to protect the cable during storage, transportation, and handling, ensuring it reaches the installation site in optimal condition.
Spool Packaging:
  • Wooden Spools: Used for 100m and 250m lengths. Spools have a diameter of 400mm (100m) and 600mm (250m), with plywood flanges reinforced with steel rings to prevent warping. The cable is secured to the spool with steel strapping to prevent unwinding.

  • Steel Spools: Used for 500m lengths, with a diameter of 800mm and steel flanges to support the heavier cable weight. Steel spools are reusable, making them cost-effective for large installations.

Protective Layers:
  • The cable on each spool is wrapped with a UV-resistant polyethylene film to protect against dust, moisture, and sunlight. This film is permeable to air, preventing condensation buildup during storage.

  • For long-term storage (over 6 months), a layer of kraft paper is added between the cable and the polyethylene film to absorb any moisture, reducing the risk of sheath degradation.

Labeling:
  • Each spool features a durable, weather-resistant label with the following information:

    • Cable type (4X6mm² or 4X6mm² + 1X8mm²)

    • Conductor material (copper) and insulation/sheath material (PVC)

    • Voltage rating (0.6/1kV)

    • Length of cable on the spool

    • Batch number and production date

    • Compliance marks (CE, IEC, ISO 9001)

    • Handling instructions: “Store in Dry Area,” “Maximum Stacking Height: 2 Spools,” “Use Forklift Here”

Palletization:
  • Smaller spools (100m and 250m) are palletized on wooden pallets (1200x800mm) with a maximum of 5 spools per pallet. Pallets are shrink-wrapped to secure the spools and protect against damage during transportation.

6. Transportation

Transportation procedures are designed to prevent damage to the cable, ensuring it arrives at its destination in good condition.
Mode of Transport:
  • Road: Flatbed trucks with spool-holding racks are used for short to medium distances. Spools are secured with chains and anti-slip mats to prevent movement during transit. Enclosed trucks are used in rainy or snowy conditions to protect against moisture.

  • Rail: Railcars with specialized spool cradles are used for long-distance transportation. Spools are spaced to avoid contact, and padding is placed between them to prevent abrasion.

  • Sea/Air: For international shipments, spools are loaded into shipping containers. Steel spools are secured to the container floor with twist locks, while wooden spools are strapped down. Desiccants are placed in the container to control humidity.

Handling Procedures:
  • Spools are lifted using forklifts with padded tines or cranes with soft slings (nylon webbing) to avoid damaging the flanges. Never lift a spool by the cable itself, as this can stretch or damage the conductors.

  • During loading/unloading, the cable end is secured to the spool to prevent unwinding. Spools are placed upright to maintain stability, and never stacked beyond the recommended height.

Environmental Controls:
  • The cable is transported at temperatures between -20°C and 50°C. In cold climates, spools are wrapped in insulation blankets to prevent the PVC sheath from becoming brittle. In hot climates, reflective tarps are used to avoid overheating, which can soften the sheath.

7. Delivery

The delivery process ensures timely and accurate distribution, with clear communication and documentation to facilitate smooth installation.
Order Processing:
  • Orders are confirmed within 24 hours of placement, with an estimated delivery date provided

based on stock availability. Custom lengths (e.g., 75m, 300m) are processed within 48 hours, with production lead times communicated upfront.
  • Order Tracking: Customers receive a unique tracking number via email or SMS, allowing real-time monitoring of shipment status through the supplier’s online portal or third-party logistics platforms (e.g., DHL, FedEx).

Delivery Scheduling:
  • Residential and Small Commercial Deliveries: Scheduled within a 2-hour window to minimize disruption. Delivery personnel contact the customer 30 minutes prior to arrival for coordination.

  • Industrial and Large-Scale Deliveries: Coordinated with site managers to align with construction timelines. Deliveries are often scheduled during off-peak hours (early morning or late afternoon) to avoid site congestion.

Unloading Assistance:
  • For heavy steel spools (500m lengths), delivery teams provide forklift assistance to unload and position spools at the customer’s designated storage area, ensuring safe handling.

Receipt Verification:
  • Upon delivery, the customer is asked to inspect the spool for visible damage (e.g., bent flanges, torn protective film) and verify the cable length and specification against the delivery note. Any discrepancies must be noted on the receipt and reported to the supplier within 48 hours.

Documentation Handover:
  • Along with the physical delivery, the customer receives a package containing:

    • A signed delivery note (copy for customer records)

    • Test certificates (insulation resistance, conductor resistance, flame retardancy)

    • Installation guidelines (including bending radius charts and termination recommendations)

    • Material safety data sheets (MSDS) for PVC and copper components

8. Samples

Samples are provided to enable customers to evaluate cable quality, compatibility, and performance before placing bulk orders, ensuring alignment with project requirements.
Sample Availability:
  • 1m-5m samples of both configurations (4X6mm² and 4X6mm² + 1X8mm²) are available free of charge for qualified customers (e.g., contractors, electrical engineers). Samples include cross-sectional cuts to showcase conductor stranding, insulation thickness, and armouring structure.

Sample Processing:
  • Samples are shipped within 2 business days of request via express courier. Each sample is labeled with the same batch number as full-length cables to ensure representativeness.

Sample Testing Support:
  • Suppliers provide a “sample testing guide” outlining recommended checks, such as:

    • Visual inspection of insulation and sheath uniformity

    • Measurement of conductor diameter and insulation thickness using calipers

    • Flexibility testing (bending to the minimum radius)

    • Adhesion testing (peeling the sheath from the armouring to check bond strength)

Custom Samples:
  • For specialized requirements (e.g., alternative sheath colors for phase identification), custom samples can be produced within 5 business days at a nominal fee, which is refundable upon bulk order placement.

9. After-Sales Service

Comprehensive after-sales support ensures customers receive ongoing assistance, from installation guidance to issue resolution, enhancing long-term satisfaction.
Technical Support:
  • Pre-Installation Consultation: Engineers are available via phone, email, or video call to advise on installation methods (e.g., direct burial depth, conduit sizing) and compatibility with connectors or terminations.

  • On-Site Assistance: For large projects, suppliers offer on-site technical visits to supervise initial cable laying, ensuring compliance with installation standards (e.g., IEC 60364).

Warranty Coverage:
  • A 5-year warranty covers manufacturing defects, including:

    • Insulation breakdown due to material flaws

    • Armouring detachment or corrosion (under normal operating conditions)

    • Conductor resistance exceeding specified limits

  • The warranty excludes damage from improper installation (e.g., exceeding bending radius), mechanical abuse, or exposure to extreme conditions beyond rated parameters (e.g., temperatures above 70°C).

Claims Processing:
  • Warranty claims are initiated by submitting a detailed report (with photos) of the issue. Suppliers typically respond within 24 hours, with a technical team dispatched for inspection if required. Approved claims result in free replacement or repair, with expedited shipping for critical applications.

Maintenance Guidance:
  • Customers receive a maintenance manual outlining:

    • Periodic inspection schedules (e.g., quarterly checks for sheath damage, annual insulation resistance testing)

    • Cleaning procedures for cables in dusty or corrosive environments

    • Repair methods for minor sheath damage (e.g., using PVC repair tape)

Training Programs:
  • Suppliers offer online or on-site training sessions for electricians and installers, covering:

    • Proper cable handling to avoid armouring damage

    • Termination techniques (e.g., crimping, heat shrink sleeves)

    • Safety protocols during installation (e.g., lockout/tagout procedures)

Feedback Mechanism:
  • A dedicated customer service team collects feedback on cable performance, delivery experience, and support quality. This input is used to refine manufacturing processes, packaging, and service offerings, ensuring continuous improvement.

In conclusion, the PVC Cable 4X6mm²/4X6mm 8mm Cu PVC Armoured Power Cable combines robust design, versatile performance, and comprehensive support to meet the demands of low-voltage power distribution. From its high-purity Copper Conductors and Flame-Retardant Insulation to its protective armouring and durable sheath, every component is engineered for reliability. Supported by meticulous packaging, efficient transportation, and responsive after-sales service, this cable delivers consistent performance across residential, commercial, and industrial applications, making it a trusted choice for electrical professionals worldwide.
Kablo ürünleri hakkında daha fazla bilgi edinin
Hongtai Cable Technology Co., Ltd ile iletişime geçin
Bize Ulaşın

Hongtai Kablo Teknoloji Co., Ltd

E-posta: Export@qlcables.com

           sales@qlcables.com

Tel/whatsapp:+86-18032066271

Ekle : Xiaokou Endüstriyel Kalkınma Bölgesi, Ningjin County, Xingtai City , Hebei Eyaleti, Çin

Telif Hakkı © Hongtai Cable Technology Co., Ltd  Teknik Destek:Ronglida teknolojisi


Site haritası

Bu web sitesi, web sitemizde en iyi deneyimi yaşamanızı sağlamak için çerezleri kullanır.

Kabul etmek reddetmek